Activity Concentration of Water Samples taken from various sites:

DATE COLLECTED

SAMPLE TYPE/SITE

ACTIVITY CONCENTRATION, mBq/L c

Iodine-131

Cesium-134

Cesium-137

April 2

Seawater/Sta. Ana, Cagayan

Not detected

Not detected

1.66 b

April 5

Freshwater/La Mesa Dam

Not detected

Not detected

Not detected

April 13

Seawater/Baler, Aurora

Not detected

Not detected

2.70 b

 

 

Activity Concentration of Fish Samples taken from Luzon:

DATE COLLECTED d

FISH TYPE/SITE

ACTIVITY CONCENTRATION, Bq/kg

Iodine-131

Cesium-134

Cesium-137

April 4

Dorado/Sta. Ana Fishport, Cagayan

Not detected

Not detected

0.164 b

April 4

Tulingan/Sta. Ana Fishport, Cagayan

Not detected

Not detected

Not detected

April 4

Bariles/Sta. Ana Fishport, Cagayan

Not detected

Not detected

Not detected

April 14

Malasugui/                Baler, Aurora

Not detected

Not detected

0.57 b

April 14

Dalagang Bukid/         Baler, Aurora

Not detected

Not detected

0.76 b

April 14

Tambakol/Baler, Aurora

Not detected

Not detected

1.09 b

April 14

Tangigue/Baler, Aurora

Not detected

Not detected

Not detected

 

 Ambient Gamma Radiation Dose Rate Measurements taken at PNRI and various provinces in Luzon since March 2011:

Location

No. of Measurements

Dose Rate (nSv/h)

REMARKS

Range

Mean

PNRI

41

93 – 106

101 ± 3

Normal

Batanes

15

65 – 85

76

Normal

Aurora

14

48 – 66

57 ± 6

Normal

Nueva Ecija

6

52 – 71

66 ± 7

Normal

Camarines Norte

11

59 – 95

84 ±10

Normal

 

a microbecquerels per cubic meter; 1 microbecquerel = 1 x 10-6 becquerel

b The above Cesium-137 levels in the soil, water, and fish samples are within background levels. The Cesium-137 is residual activity from atmospheric nuclear weapons testing in the 1950’s and 1960’s, not from the Fukushima accident. 

c millibecquerels per liter; 1 millibecquerel = 1 x 10-3 becquerel; some copies of Information Bulletin No.22 may have erroneously stated this as Bq/kg instead of mBq/L

Dates corrected